PREFERRED DISTRIBUTORS INC -- CHEWING GUM REMOVER, 835 -- 7930-00N049954
===================== Product Identification =====================
Product ID:CHEWING GUM REMOVER, 835
MSDS Date:12/12/1989
FSC:7930
NIIN:00N049954
=== Responsible Party ===
Company Name:PREFERRED DISTRIBUTORS INC
Address:1107 HAZELTINE BLVD
City:CHASKA
State:MN
ZIP:55318
Country:US
Info Phone Num:708-543-7600
Emergency Phone Num:800-228-5635
CAGE:PREFE
=== Contractor Identification ===
Company Name:PREFERRED DISTRIBUTORS INC
Address:8301 BROADWAY, SUITE 301
Box:City:SAN ANTONIO
State:TX
ZIP:78209
Country:US
Phone:210-930-1191
CAGE:PREFE
============= Composition/Information on Ingredients =============
Ingred Name:METHANE, CHLORODIFLUORO-; (CHLORODIFLUOROMETHANE)
CAS:75-45-6
RTECS #:PA6390000
Fraction by Wt: 35%
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM
Ozone Depleting Chemical:2
Ingred Name:PROPANE, 2-METHYL-
CAS:75-28-5
RTECS #:TZ4300000
Fraction by Wt: 65%
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:SUPDAT:UV RADIATION MAY CAUSE THE FORMATION OF CHLORIDES,
FLUORIDES & PHOSGENE .
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE & CHRONIC:OVEREXPOS BY INHAL MAY
INITIALLY INCLUDE:NONSPECIFIC DISCOMFORT SUCH AS NAUS, HDCH,
WEAKNESS. HIGHER IRREGULARITIES, UNCON, OR DEATH. SKIN
CONT:PROPELLANT VAPORIZES RAPIDLY AT AMBIENT TEMP, THEREFORE, LIQ
MAY CAUSE FROSTBITE. CHLOROCARBON (CFC) MATLS HAVE PRODUCED
SENSITIZATION OF THE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:MYOCARDIUM TO EPINEPHRINE IN
LABORATORY ANIMALS AND COULD HAVE A SIMILAR EFFECT IN HUMANS.
ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT
FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED
TO CHLOROCARBONS .
Medical Cond Aggravated by Exposure:INDIVIDUALS W/PREEXISTING DISEASES
OF THE CNS OR CARDIOVASCULAR SYSTEM MAY HAVE INCREASED
SUSCEPTIBILITY TO TOXCITY OF EXCESSIVE EXPOSURES.
======================= First Aid Measures =======================
First Aid:EYES:IMMEDIATELY FLUSH W/POTABLE WATER FOR MINIMUM OF 15
MINUTES, SEEK ASSISTANCE FROM MD . SKIN:FLUSH W/COPIOUS AMOUNTS OF
WATER. CALL MD . INHAL:IMMED REMOVE TO FRESH AIR. KEEP PERSON CA
LM. IF NOT BRTHG, GIVE ARTF RESP. IF BRTHG IS DFCLT, GIVE OXYGEN.
CALL PHYS. INGEST:IF SWALLOWED INGEST IS NOT CONSIDERED A POTENTIAL
ROUTE OF EXPOS. NOTE TO PHYS:BECAUSE OF POSS DISTURBANCES (SUPDAT)
===================== Fire Fighting Measures =====================
Lower Limits:1.5/2.9%
Upper Limits:7.7/10.9%
Extinguishing Media:WATER SPRAY OR FOG, "ALCOHOL" FOAM, DRY CHEMICAL
CARBON DIOXIDE.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD PRESS DEMAND SCBA & FULL
PROT EQUIP . CNTNRS SHOULD BE COOLED W/WATER TO PVNT VAP PRESS
BUILD UP. USE EQUIP/SHIELDING, (SUPDAT)
Unusual Fire/Explosion Hazard:AT ELEVATED TEMPERATURE OVER (54C=130F),
CONTAINERS MAY VENT, RUPTURE OR BURST. THERMAL DECOMP PRODS MAY
INCL CHLORIDES, FLUORIDES AND PHOSGENE .
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT & VENT AREA. SOAK
UP SPILL W/AN INERT ABSORB & PLACE INTO A DESIGNATED DISPOSAL
CONTAINER. CONSULT LOCAL REGULATORY AGENCY FOR PROPER DISPOSITION
OF MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID BREATHING VAPOR. KEEP AWAY FROM
HEAT AND FLAME. USE WITH ADEQUATE VENTILATION. DO NOT PUNCUTURE OR
INCINERATE CONTAINERS.
Other Precautions:PLEASE READ & FOLLOW DIRECTIONS ON PROD LABEL; THEY
ARE YOUR BEST GUIDE TO USING THIS PROD IN THE MOST EFFECTIVE WAY, &
GIVE NEC SFTY PRECAUT TO PROTECT YOUR HLTH. NO SMOK IN AREA OF USE.
DO NOT USE I N GEN VICINITY OF ARC WELDING,(SUPDAT)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE REQD IF GOOD VENT IS MAINTAINED. IF
EXPOSURE MAY EXCEED OCCUP EXPOSURE LIMITS USE NIOSH/MSHA APPROVED
RESPIRATOR TO PREVENT OVEREXPOSURE.
Ventilation:LOCAL EXHAUST ADEQ UNDER NORM CONDITIONS. MECHANICAL
(GENERAL):OPTIONAL.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKER GOGGLES .
Other Protective Equipment:PROT CLTHG & EQUIP IN ACCORDANCE WITH 29CFR
1910.132 AND CFR 1910.133.
Work Hygienic Practices:ENSURE STRICT SANITARY CONDITIONS ARE CONFORMED
TO WHEN WORKING AROUND CHEMICALS.
Supplemental Safety and Health
VP:@130F 179PSIG. FIRE FIGHT PROC:AS REQD, TO PROT PERS FROM BURST,
RUPTURING/VENT CNTNRS. CNDTNS TO AVOID:CAUSE BURST. FIRST AID
PROC:OF CARD RHYTHM, CATECHOLAMINE DRUGS, SUCH AS EPINEPHRINE,
SHOULD BE USED W/SPEC CAUTION ONLY IN SITUATIONS OF EMER LIFE
SUPPORT. OTHER PREC:OPEN FLAMES/HOT SURFS. HEAT AND/OR (ING 3)
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:<-30F,<-34C
Vapor Pres:SUPDAT
Vapor Density:>1.0
Spec Gravity:.6921 (H*20=1)
pH:NEUT
Evaporation Rate & Reference:<1.0 (ETHER=1)
Solubility in Water:<0.20WT%@25C(77F)
Appearance and Odor:COLORLESS, SLIGHT ETHEREAL
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ALKALI OR ALKALINE EARTH METALS.
Stability Condition to Avoid:DO NOT STORE AEROSOL CNTNRS ABOVE
(49C-120F). KEEP AWAY FROM HEAT, OPEN FLAMES/SPARKS. DROPPING OF
CNTNRS COULD (SUPDAT)
Hazardous Decomposition Products:HYDROCHLORIC AND HYDROFLUORIC ACIDS,
ADDITIONAL TOXIC CHEMICALS MAY BE FORMED IN SMALL AMOUNTS. PHOSGENE
.
==================== Disposal Considerations ====================
Waste Disposal Methods:DO NOT PUNCTURE/INCINERATE CNTNRS. WHEN CONTENTS
ARE DEPLETED CONTINUE TO DEPRESS BUTTON UNTIL ALL GAS IS EXPELLED.
DISPOSE OF CONTAINER IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.